![](https://ibcon.com/main/wp-content/uploads/2023/07/breaker.jpg)
Protecting electrical installations from damage
The number of electrical loads is constantly increasing, which places an ever greater load on the electrical installation. In the event of an overload or short-circuit, miniature circuit breakers safely cut off the connected circuit and reliably protect electrical installations and equipment from damage. Miniature circuit breakers from the SENTRON portfolio are also simple to mount and install. The devices have a uniform design and, with the appropriate accessories, can be expanded by many additional functions. For industry, buildings or infrastructure – with our versatile portfolio, you will find a suitable miniature circuit breaker for any application.
Communication and measuring capable miniature circuit breakers
In addition to the protective functions of the standard devices, the communication and measuring capable MCBs bring transparency to the final circuit and can react even before the fault occurs. The system availability is increased. Information on the switching status enables predictive maintenance.The standard 5SY MCBs, 5SP4 MCBs and 5SL MCBs can be easily expanded with the communication and measuring capable auxiliary witch / fault signal contact.
![](https://ibcon.com/main/wp-content/uploads/2023/07/breaker_02.jpg)
Specifications
Article Number | 5SL6206-7 | 5SL6216-7 |
Model | ||
product brand name | SENTRON | SENTRON |
product description | Miniature circuit breaker 400 V 6kA, 2-pole, C, 6A | Miniature circuit breaker 400 V 6kA, 2-pole, C, 16A |
General technical data | ||
number of poles | 2 | 2 |
design of pole | 2P | 2P |
tripping characteristic class | C | C |
mechanical service life (operating cycles) typical | 10 000 | 10 000 |
overvoltage category | III | III |
degree of pollution | 2 | 2 |
Voltage | ||
type of voltage of the operating voltage | AC | AC |
insulation voltage (Ui) ● with multi-phase operation at AC rated value | 440 V | 440 V |
Supply voltage | ||
supply voltage at AC rated value | 400 V | 400 V |
value range of the supply voltage frequency | 50/60 Hz | 50/60 Hz |
operating voltage ● with multi-phase operation at AC maximum ● at DC rated value maximum | 440 V 72 V | 440 V 72 V |
Protection class | ||
protection class IP | IP20, with connected conductors | IP20, with connected conductors |
Switching capacity | ||
switching capacity current ● according to EN 60898 rated value ● according to IEC 60947-2 rated value | 6 kA 6 kA | 6 kA 6 kA |
energy limitation class | 3 | 3 |
Dissipation | ||
power loss [W] for rated value of the current at AC in hot operating state per pole | 0.7 W | 1.8 W |
suitability for operation | Residential buildings/infrastructure | Residential buildings/infrastructure |
Product details | ||
product feature ● halogen-free ● sealable ● silicon-free | Yes Yes Yes | Yes Yes Yes |
product extension installable supplementary devices | Yes | Yes |
Connections | ||
connectable conductor cross-section solid ● minimum ● maximum | 0.75 mm² 25 mm² | 0.75 mm² 25 mm² |
connectable conductor cross-section stranded ● minimum ● maximum | 0.75 mm² 25 mm² | 0.75 mm² 25 mm² |
connectable conductor cross-section finely stranded with core end processing ● minimum ● maximum | 0.75 mm² 25 mm² | 0.75 mm² 25 mm² |
tightening torque with screw-type terminals ● minimum ● maximum | 2.5 N·m 3 N·m | 2.5 N·m 3 N·m |
Mechanical Design | ||
height | 90 mm | 90 mm |
width | 36 mm | 36 mm |
depth | 76 mm | 76 mm |
installation depth | 70 mm | 70 mm |
number of modular width units | 2 | 2 |
mounting position | any | any |
net weight | 235 g | 230 g |
Environmental conditions | ||
ambient temperature during operation ● minimum ● maximum | -25 °C 45 °C | -25 °C 45 °C |
ambient temperature during storage ● minimum ● maximum | -40 °C 75 °C | -40 °C 75 °C |