SIMATIC IPC377E

SIMATIC IPC377E ( 6AV7230-0CA20-0AA0 )

  • SIMATIC IPC377E (Basic panel PC)
  • Celeron N3160 (4C/4T)
  • 1x display port graphic
  • 1x VGA port graphic
  • 2x 10/100/1000 Mbit/s Ethernet RJ45
  • 2x USB3.0, 2x USB2.0
  • 4x serial ports (COM)
  • 12″ touch (1280 x 800)
  • 4 GB RAM
  • 1x mPCIe / 1x mSATA
  • Without operating system
  • Without drive
  • 24 V DC power supply
  • installation, VESA mounting

Specification

General information
Product type designationIPC377E
Installation type/mounting
MountingPanel mount and VESA, horizontal and vertical
DesignPanel PC, built-in unit
Supply voltage
Type of supply voltage24 V DC
Mains buffering
● Mains/voltage failure stored energy time

10 ms
Processor
Processor typeIntel Celeron N3160
Drives
Hard disk500 GB HDD
SSDYes; 256 GB SSD
Memory
Type of memoryDDR3L
Main memory4 GB, 8 GB
Capacity of main memory, max.8 Gbyte
Hardware configuration
Slots
● free slots

1x mPCIe (half-size), 1x mSATA (full-size)
Interfaces
Number of industrial Ethernet interfaces2; 2x RJ45 (independent)
USB port2x USB 2.0, 2x USB 3.0 (high current)
Video interfaces
● Graphics interface

1x DisplayPort, 1x VGA
Industrial Ethernet
● Industrial Ethernet interface
— 100 Mbps
— 1000 Mbps

2x Ethernet (RJ45)
Yes
Yes
Protocols
Protocols (Ethernet)
● TCP/IP

Yes
Integrated Functions
Monitoring functions
● Temperature monitoring
● Watchdog
● Status LEDs
● Fan

Yes
Yes
POWER, HDD
No
EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of static electricity


±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)
Interference immunity against high-frequency electromagnetic fields
● Interference immunity against high frequency radiation


10 V/m for 80 … 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 … 6 GHz, 80 % AM according to IEC 61000-4-3
Interference immunity to cable-borne interference
● Interference immunity on supply cables


±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)
● Interference immunity on signal cables >30m±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge
● Interference immunity on signal cables < 30m±1 kV acc. to IEC 61000-4-4, Burst
Interference immunity against voltage surge
● asymmetric interference
● symmetric interference

±2 kV acc. to IEC 61000-4-5, surge asymmetric
±1 kV acc. to IEC 61000-4-5, surge symmetric
Interference immunity to magnetic fields
● Interference immunity to magnetic fields at 50 Hz

100 A/m; to IEC 61000-4-8
Degree and class of protection
IP (at the front)IP65
IP (rear)IP40
Standards, approvals, certificates
CE markYes
UL approvalYes
cULusYes
RCM (formerly C-TICK)Yes
EAC (formerly Gost-R)Yes
FCCYes
Dust protectionProtection against foreign bodies > 1 mm
Ambient conditions
Ambient temperature during operation
● min.
● max.

0 °C
45 °C
Ambient temperature during
storage/transportation

● min.
● max.


-20 °C
60 °C
Relative humidity
● Relative humidity

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)
Vibrations
● Vibration resistance during operation acc. to IEC 60068-2-6

tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s² (1 g)
Shock testing
● Shock load during operation

Tested in accordance with IEC 60068-2-27: With SSD: 150 m/s², 11 ms; with HDD: 9.8 m/s², 20 ms
Operating systems
pre-installed operating systemWindows 7 Ultimate (Multi-Language), 64 bit; Windows 10 Enterprise 2016 LTSB, 64 bit
without operating systemYes