{"id":4638,"date":"2023-07-06T04:23:04","date_gmt":"2023-07-06T04:23:04","guid":{"rendered":"https:\/\/ibcon.com\/main\/?p=4638"},"modified":"2023-07-11T05:00:42","modified_gmt":"2023-07-11T05:00:42","slug":"logo-dm16-24r-expansion-module","status":"publish","type":"post","link":"https:\/\/ibcon.com\/main\/brand\/siemens-product\/logo-dm16-24r-expansion-module\/","title":{"rendered":"LOGO! DM16 24R expansion module"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"300\" height=\"300\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6ED1055-1NB10-0BA2.jpg\" alt=\"\" class=\"wp-image-4639\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6ED1055-1NB10-0BA2.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6ED1055-1NB10-0BA2-150x150.jpg 150w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6ED1055-1NB10-0BA2-116x116.jpg 116w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>LOGO! DM16 24R expansion module<\/strong><br>[ 6ED1055-1NB10-0BA2 ]<\/h3>\n\n\n\n<p>LOGO! DM16 24R expansion module, PS\/I\/O: 24 V DC\/24 V DC\/relay, 8 DI\/8 DO, 4 MW for LOGO! 8<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-1\"><\/div>\n\n\n\n<p><strong>Specification<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Installation type\/mounting<\/strong><\/td><\/tr><tr><td>Mounting<\/td><td>on 35 mm DIN rail, 4 spacing units wide<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Supply voltage<\/strong><\/td><\/tr><tr><td>Rated value (DC)<br>  \u25cf 24 V DC<\/td><td><br>Yes<\/td><\/tr><tr><td>permissible range, lower limit (DC)<\/td><td>20.4 V<\/td><\/tr><tr><td>permissible range, upper limit (DC)<\/td><td>28.8 V<\/td><\/tr><tr><td>Rated value (AC)<br>  \u25cf 24 V AC<\/td><td><br>No<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Digital inputs<\/strong><\/td><\/tr><tr><td>Number of digital inputs<\/td><td>8<\/td><\/tr><tr><td>Input voltage<br>  \u25cf Type of input voltage<br>  \u25cf for signal &#8220;0&#8221;<br>  \u25cf for signal &#8220;1&#8221;<\/td><td><br>DC<br>&lt; 5 V DC<br>12 V DC<\/td><\/tr><tr><td>Input current<br>  \u25cf for signal &#8220;0&#8221;, max. (permissible quiescent current)<br>  \u25cf for signal &#8220;1&#8221;, typ<\/td><td><br>0.85 mA<br>2 mA<\/td><\/tr><tr><td>Input delay (for rated value of input voltage) for standard inputs<br>  \u2014 at &#8220;0&#8221; to &#8220;1&#8221;, max.<br>  \u2014 at &#8220;1&#8221; to &#8220;0&#8221;, max.<\/td><td><br>1.5 ms<br>1.5 ms<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Digital outputs<\/strong><\/td><\/tr><tr><td>Number of digital outputs<\/td><td>8; Relays<\/td><\/tr><tr><td>Short-circuit protection<\/td><td>No<\/td><\/tr><tr><td>Controlling a digital input<\/td><td>Yes<\/td><\/tr><tr><td>Switching capacity of the outputs<br>  \u25cf on lamp load, max.<\/td><td><br>1 000 W<\/td><\/tr><tr><td>Output current<br>  \u25cf for signal &#8220;1&#8221; rated value<br>  \u25cf for signal &#8220;1&#8221; minimum load current<\/td><td><br>5 A<br>100 mA<\/td><\/tr><tr><td>Parallel switching of two outputs<br>  \u25cf for uprating<\/td><td><br>No<\/td><\/tr><tr><td>Switching frequency<br>  \u25cf with resistive load, max.<br>  \u25cf with inductive load, max.<br>  \u25cf mechanical, max.<\/td><td><br>2 Hz<br>0.5 Hz<br>10 Hz<\/td><\/tr><tr><td>Relay outputs<br>Switching capacity of contacts<br>  \u2014 with inductive load, max<br>  \u2014 with resistive load, max<\/td><td><br><br>3 A<br>5 A<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>EMC<\/strong><\/td><\/tr><tr><td>Emission of radio interference acc. to EN 55 011<br>  \u25cf Limit class B, for use in residential areas<\/td><td><br>Yes<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Degree and class of protection<\/strong><\/td><\/tr><tr><td>IP degree of protection<\/td><td>IP20<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Standards, approvals, certificates<\/strong><\/td><\/tr><tr><td>CE mark<\/td><td>Yes<\/td><\/tr><tr><td>CSA approval<\/td><td>Yes<\/td><\/tr><tr><td>UL approval<\/td><td>Yes<\/td><\/tr><tr><td>FM approval<\/td><td>Yes<\/td><\/tr><tr><td>developed in accordance with IEC 61131<\/td><td>Yes<\/td><\/tr><tr><td>according to VDE 0631<\/td><td>Yes<\/td><\/tr><tr><td>Marine approval<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Ambient conditions<\/strong><\/td><\/tr><tr><td>Ambient temperature during operation<br>  \u25cf min.<br>  \u25cf max.<\/td><td><br>0 \u00b0C; ES03 and higher: -20 \u00b0C<br>55 \u00b0C<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Dimensions<\/strong><\/td><\/tr><tr><td>Width<\/td><td>71.5 mm<\/td><\/tr><tr><td>Height<\/td><td>90 mm<\/td><\/tr><tr><td>Depth<\/td><td>58 mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>LOGO! DM16 24R expansion module[ 6ED1055-1NB10-0BA2 ] LOGO! DM16 24R expansion module, PS\/I\/O: 24 V DC\/24 V DC\/relay, 8 DI\/8 DO, 4 MW for LOGO! 8 Specification<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[28],"tags":[42,33,40],"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Khwanjai Nampromma","author_link":"https:\/\/ibcon.com\/main\/author\/khwanjai\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/ibcon.com\/main\/category\/brand\/siemens-product\/\" rel=\"category tag\">SIEMENS Product<\/a>","rttpg_excerpt":"LOGO! DM16 24R expansion module[ 6ED1055-1NB10-0BA2 ] LOGO! DM16 24R expansion module, PS\/I\/O: 24 V DC\/24 V DC\/relay, 8 DI\/8 DO, 4 MW for LOGO! 8 Specification","_links":{"self":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4638"}],"collection":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/comments?post=4638"}],"version-history":[{"count":15,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4638\/revisions"}],"predecessor-version":[{"id":4740,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4638\/revisions\/4740"}],"wp:attachment":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/media?parent=4638"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/categories?post=4638"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/tags?post=4638"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}