{"id":4710,"date":"2023-07-11T03:22:47","date_gmt":"2023-07-11T03:22:47","guid":{"rendered":"https:\/\/ibcon.com\/main\/?p=4710"},"modified":"2023-07-11T04:55:34","modified_gmt":"2023-07-11T04:55:34","slug":"logo-csm-12-24","status":"publish","type":"post","link":"https:\/\/ibcon.com\/main\/brand\/siemens-product\/logo-csm-12-24\/","title":{"rendered":"LOGO! CSM 12\/24"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"300\" height=\"300\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6GK7177-1MA20-0AA0.jpg\" alt=\"\" class=\"wp-image-4711\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6GK7177-1MA20-0AA0.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6GK7177-1MA20-0AA0-150x150.jpg 150w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6GK7177-1MA20-0AA0-116x116.jpg 116w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>LOGO! CSM12\/24 Compact Switch Module<\/strong><br><strong>[ 6GK7177-1MA20-0AA0 ]<\/strong><\/h3>\n\n\n\n<p>LOGO! CSM12\/24 Compact Switch Module connection of a LOGO! (.<br>..0BA7\/\u20260BA8) and up to 3 further nodes to Ind. Ethernet with 10\/100 Mbit\/s<br>Unmanaged switch, 4 RJ45 ports, 1x front port for diagnostics DC 12\/24V power<br>supply LED diagnostics, LOGO! setup.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>Specification<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table alignleft\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>product type designation<\/strong><\/td><td><strong>LOGO! CSM 12\/24<\/strong><\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>transfer rate<\/strong><\/td><\/tr><tr><td>transfer rate<\/td><td>10 Mbit\/s, 100 Mbit\/s<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>interfaces \/ for communication \/ maximum configuration for modular devices<\/strong><\/td><\/tr><tr><td>number of electrical ports \/ maximum<\/td><td>4<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>interfaces \/ for communication \/ integrated<\/strong><\/td><\/tr><tr><td>number of electrical connections<br>  \u25cf for network components or terminal equipment<\/td><td><br>4<\/td><\/tr><tr><td>number of 100 Mbit\/s SC ports<br>  \u25cf for multimode<\/td><td><br>0<\/td><\/tr><tr><td>number of 1000 Mbit\/s LC ports<br>  \u25cf for multimode<br>  \u25cf for single mode (LD)<\/td><td><br>0<br>0<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>interfaces \/ other<\/strong><\/td><\/tr><tr><td>number of electrical connections<br>  \u25cf for power supply<\/td><td><br>1<\/td><\/tr><tr><td>type of electrical connection<br>  \u25cf for power supply<\/td><td><br>3-pole terminal block<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>supply voltage, current consumption, power loss<\/strong><\/td><\/tr><tr><td> <strong>type of voltage \/ 1 \/ of the supply voltage<\/strong><br>  \u25cf supply voltage \/ 1 \/ rated value<br>  \u25cf power loss [W] \/ 1 \/ rated value<br>  \u25cf supply voltage \/ 1 \/ rated value<br>  \u25cf consumed current \/ 1 \/ maximum<br>  \u25cf type of electrical connection \/ 1 \/ for power supply<br>  \u25cf product component \/ 1 \/ fusing at power supply input<\/td><td>DC<br>24 V<br>1.5 W<br>10.2 \u2026 30.2 V<br>0.15 A<br>3-pole terminal block<br>Yes<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>ambient conditions<\/strong><\/td><\/tr><tr><td>ambient temperature<br>  \u25cf during operation<br>  \u25cf during storage<br>  \u25cf during transport<\/td><td><br>0 \u2026 55 \u00b0C<br>-40 \u2026 +70 \u00b0C<br>-40 \u2026 +70 \u00b0C<\/td><\/tr><tr><td>relative humidity<br>  \u25cf at 25 \u00b0C \/ without condensation \/ during operation \/<br>maximum<\/td><td><br>90 %<br><\/td><\/tr><tr><td>protection class IP<\/td><td>IP20<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>design, dimensions and weights<\/strong><\/td><\/tr><tr><td>design<\/td><td>LOGO! module<\/td><\/tr><tr><td>width<\/td><td>71.5 mm<\/td><\/tr><tr><td>height<\/td><td>90 mm<\/td><\/tr><tr><td>depth<\/td><td>58.2 mm<\/td><\/tr><tr><td>net weight<\/td><td>0.15 kg<\/td><\/tr><tr><td>fastening method<br>  \u25cf 35 mm top hat DIN rail mounting<br>  \u25cf wall mounting<br>  \u25cf S7-300 rail mounting<br>  \u25cf S7-1500 rail mounting<\/td><td><br>Yes<br>Yes<br>No<br>No<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>product functions \/ management, configuration, engineering<\/strong><\/td><\/tr><tr><td>product function<br>  \u25cf multiport mirroring<\/td><td><br>No<\/td><\/tr><tr><td>product function \/ switch-managed<\/td><td>No<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>standards, specifications, approvals<\/strong><\/td><\/tr><tr><td>standard<br>  \u25cf for safety \/ from CSA and UL<\/td><td><br>UL 508, CSA C22.2 No. 142<\/td><\/tr><tr><td>reference code<br>  \u25cf according to IEC 81346-2<br>  \u25cf according to IEC 81346-2:2019<\/td><td><br>KF<br>KFE<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>standards, specifications, approvals \/ CE<\/strong><\/td><\/tr><tr><td>certificate of suitability \/ CE marking<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>standards, specifications, approvals \/ hazardous environments<\/strong><\/td><\/tr><tr><td>standard \/ for hazardous zone<br><br>\u25cf from CSA and UL<br><\/td><td>ATEX: EN 60079-0 : 2009,EN 60079-15 :2010 (Directive 94\/9\/EC), IECEx: IEC 60079-0 :2011, IEC 60079-15 :2010<br>Haz-Loc ANSI\/ISA 12.12.01: CL. I, Div2, Group A,B,C,D T4, CL I, Zone 2,Group IIC, T4, Ta=55\u00b0C<\/td><\/tr><tr><td>certificate of suitability<br>  \u25cf CCC \/ for hazardous zone according to GB standard<br>  \u25cf CCC \/ for hazardous zone according to GB standard \/ as<br>marking<\/td><td><br>Yes<br>Ex nA IIC T4 Gc<br><\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>standards, specifications, approvals \/ other<\/strong><\/td><\/tr><tr><td>certificate of suitability<br>  \u25cf C-Tick<br>  \u25cf KC approval<\/td><td><br>Yes<br>No<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>standards, specifications, approvals \/ marine classification<\/strong><\/td><\/tr><tr><td>Marine classification association<br>  \u25cf American Bureau of Shipping Europe Ltd. (ABS)<br>  \u25cf French marine classification society (BV)<br>  \u25cf Det Norske Veritas (DNV)<br>  \u25cf Germanische Lloyd (GL)<br>  \u25cf Lloyds Register of Shipping (LRS)<br>  \u25cf Nippon Kaiji Kyokai (NK)<br>  \u25cf Polski Rejestr Statkow (PRS)<\/td><td><br>No<br>No<br>No<br>No<br>No<br>No<br>No<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>LOGO! CSM12\/24 Compact Switch Module[ 6GK7177-1MA20-0AA0 ] LOGO! CSM12\/24 Compact Switch Module connection of a LOGO! (&#8230;0BA7\/\u20260BA8) and up to 3 further nodes to Ind. Ethernet with 10\/100 Mbit\/sUnmanaged switch, 4 RJ45 ports, 1x front port for diagnostics DC 12\/24V powersupply LED diagnostics, LOGO! setup. Specification<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[28],"tags":[42,33,40],"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Khwanjai Nampromma","author_link":"https:\/\/ibcon.com\/main\/author\/khwanjai\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/ibcon.com\/main\/category\/brand\/siemens-product\/\" rel=\"category tag\">SIEMENS Product<\/a>","rttpg_excerpt":"LOGO! CSM12\/24 Compact Switch Module[ 6GK7177-1MA20-0AA0 ] LOGO! CSM12\/24 Compact Switch Module connection of a LOGO! (...0BA7\/\u20260BA8) and up to 3 further nodes to Ind. Ethernet with 10\/100 Mbit\/sUnmanaged switch, 4 RJ45 ports, 1x front port for diagnostics DC 12\/24V powersupply LED diagnostics, LOGO! setup. Specification","_links":{"self":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4710"}],"collection":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/comments?post=4710"}],"version-history":[{"count":3,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4710\/revisions"}],"predecessor-version":[{"id":4732,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4710\/revisions\/4732"}],"wp:attachment":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/media?parent=4710"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/categories?post=4710"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/tags?post=4710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}