{"id":4754,"date":"2023-07-11T06:48:41","date_gmt":"2023-07-11T06:48:41","guid":{"rendered":"https:\/\/ibcon.com\/main\/?p=4754"},"modified":"2024-12-11T08:58:12","modified_gmt":"2024-12-11T08:58:12","slug":"6es7241-1ch30-1xb0","status":"publish","type":"post","link":"https:\/\/ibcon.com\/main\/brand\/siemens-product\/6es7241-1ch30-1xb0\/","title":{"rendered":"SIMATIC S7-1200, Communication Board CB 1241 (6ES7241-1CH30-1XB0)"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"300\" height=\"300\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6ES7241-1CH30-1XB0.jpg\" alt=\"\" class=\"wp-image-4755\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6ES7241-1CH30-1XB0.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6ES7241-1CH30-1XB0-150x150.jpg 150w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/6ES7241-1CH30-1XB0-116x116.jpg 116w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>6ES7241-1CH30-1XB0<br>SIMATIC S7-1200, Communication Board CB 1241<\/strong><\/h3>\n\n\n\n<p>SIMATIC S7-1200, Communication Board CB 1241, RS485, terminal block, supports Freeport<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>Specification<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>General information<\/strong><\/td><\/tr><tr><td>Product type designation<\/td><td>CB 1241 RS 485<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Input current<\/strong><\/td><\/tr><tr><td>from backplane bus 5 V DC, typ.<\/td><td>50 mA<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Power loss<\/strong><\/td><\/tr><tr><td>Power loss, typ.<\/td><td>1.5 W<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Interfaces<\/strong><\/td><\/tr><tr><td>Point-to-point connection<br>  \u25cf Cable length, max<\/td><td><br>1 000 m<\/td><\/tr><tr><td>Integrated protocol driver<br>\u2014 Freeport<br>\u2014 ASCII<br>\u2014 Modbus RTU master<br>\u2014 MODBUS RTU slave<br>\u2014 USS<\/td><td><br>Yes<br>Yes; Available as library function<br>Yes<br>Yes<br>Yes; Available as library function<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Protocols<\/strong><\/td><\/tr><tr><td><strong>Integrated protocols<\/strong><br>Freeport<br>\u2014 Telegram length, max<br>\u2014 Bits per character<br>\u2014 Number of stop bits<br>\u2014 Parity<br><br><\/td><td><br><br>1 kbyte<br>7 or 8<br>1 (Standard), 2<br>No parity (standard); even, uneven, mark (parity bit always 1); space (parity bitalways 0)<\/td><\/tr><tr><td>3964 (R)<br>\u2014 Telegram length, max.<br>\u2014 Bits per character<br>\u2014 Number of stop bits<br>\u2014 Parity<br><br><\/td><td><br>1 kbyte<br>7 or 8<br>1 (Standard), 2<br>No parity (standard); even, uneven, mark (parity bit always 1); space (parity bit always 0)<\/td><\/tr><tr><td>Modbus RTU master<br>\u2014 Address area<br>\u2014 Number of slaves, max.<br><br><br><br><\/td><td><br>1 through 49 999 (Standard Modbus addressing)<br>247; slave numbers 1 through 247, per MODBUS network segment maximum 32 devices, additional repeaters needed to expand the network to maximum configuration<br><\/td><\/tr><tr><td>MODBUS RTU slave<br>\u2014 Address area<\/td><td><br>1 through 49 999 (Standard Modbus addressing)<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Interrupts\/diagnostics\/status information<\/strong><\/td><\/tr><tr><td>Diagnostics function<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Degree and class of protection<\/strong><\/td><\/tr><tr><td>IP degree of protection<\/td><td>IP20<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Standards, approvals, certificates<\/strong><\/td><\/tr><tr><td>CE mark<\/td><td>Yes<\/td><\/tr><tr><td>CSA approval<\/td><td>Yes<\/td><\/tr><tr><td>UL approval<\/td><td>Yes<\/td><\/tr><tr><td>cULus<\/td><td>Yes<\/td><\/tr><tr><td>FM approval<\/td><td>Yes<\/td><\/tr><tr><td>RCM (formerly C-TICK)<\/td><td>Yes<\/td><\/tr><tr><td>KC approval<\/td><td>Yes<\/td><\/tr><tr><td>Marine approval<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Ambient conditions<\/strong><\/td><\/tr><tr><td>Free fall<br>  \u25cf Fall height, max.<\/td><td><br>0.3 m; five times, in product package<\/td><\/tr><tr><td>Ambient temperature during operation<br>  \u25cf min.<br>  \u25cf max.<br>  \u25cf horizontal installation, min.<br>  \u25cf horizontal installation, max.<br>  \u25cf vertical installation, min.<br>  \u25cf vertical installation, max.<br>  \u25cf permissible temperature change<\/td><td><br>-20 \u00b0C<br>60 \u00b0C<br>-20 \u00b0C<br>60 \u00b0C<br>-20 \u00b0C<br>50 \u00b0C<br>5\u00b0C to 55\u00b0C, 3\u00b0C \/ minute<\/td><\/tr><tr><td>Ambient temperature during storage\/transportation<br>  \u25cf min.<br>  \u25cf max.<\/td><td><br><br>-40 \u00b0C<br>70 \u00b0C<\/td><\/tr><tr><td>Air pressure acc. to IEC 60068-2-13<br>  \u25cf Operation, min.<br>  \u25cf Operation, max.<br>  \u25cf Storage\/transport, min.<br>  \u25cf Storage\/transport, max.<\/td><td><br>795 hPa<br>1 080 hPa<br>660 hPa<br>1 080 hPa<\/td><\/tr><tr><td>Relative humidity<br>  \u25cf Operation at 25 \u2103 without condensation, max.<\/td><td><br>95 %<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Mechanics\/material<\/strong><\/td><\/tr><tr><td>Enclosure material (front)<br>  \u25cf Plastic<\/td><td><br>Yes<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Dimensions<\/strong><\/td><\/tr><tr><td>Width<\/td><td>38 mm<\/td><\/tr><tr><td>Height<\/td><td>62 mm<\/td><\/tr><tr><td>Depth<\/td><td>21 mm<\/td><\/tr><tr><td colspan=\"2\" style=\"background-color:#e3e3e3\"><strong>Weights<\/strong><\/td><\/tr><tr><td>Weight, approx.<\/td><td>40 g<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<ul>\n<li><\/li>\n<\/ul>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>6ES7241-1CH30-1XB0SIMATIC S7-1200, Communication Board CB 1241 SIMATIC S7-1200, Communication Board CB 1241, RS485, terminal block, supports Freeport Specification<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[28],"tags":[43,33,40],"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Khwanjai Nampromma","author_link":"https:\/\/ibcon.com\/main\/author\/khwanjai\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/ibcon.com\/main\/category\/brand\/siemens-product\/\" rel=\"category tag\">SIEMENS Product<\/a>","rttpg_excerpt":"6ES7241-1CH30-1XB0SIMATIC S7-1200, Communication Board CB 1241 SIMATIC S7-1200, Communication Board CB 1241, RS485, terminal block, supports Freeport Specification","_links":{"self":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4754"}],"collection":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/comments?post=4754"}],"version-history":[{"count":13,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4754\/revisions"}],"predecessor-version":[{"id":7872,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4754\/revisions\/7872"}],"wp:attachment":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/media?parent=4754"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/categories?post=4754"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/tags?post=4754"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}