{"id":4854,"date":"2023-07-14T05:02:55","date_gmt":"2023-07-14T05:02:55","guid":{"rendered":"https:\/\/ibcon.com\/main\/?p=4854"},"modified":"2024-12-12T09:22:47","modified_gmt":"2024-12-12T09:22:47","slug":"simatic-iot2000-input-output-module","status":"publish","type":"post","link":"https:\/\/ibcon.com\/main\/brand\/siemens-product\/simatic-iot2000-input-output-module\/","title":{"rendered":"SIMATIC IoT2000 input\/output module"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-7\">\n<div class=\"wp-block-column is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-5\">\n<div class=\"wp-block-column is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-3\">\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/SIMATICIoT2000_IO_01.jpg\" alt=\"\" class=\"wp-image-4855\" width=\"275\" height=\"275\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/SIMATICIoT2000_IO_01.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/SIMATICIoT2000_IO_01-150x150.jpg 150w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/SIMATICIoT2000_IO_01-116x116.jpg 116w\" sizes=\"(max-width: 275px) 100vw, 275px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/12\/6ES7647-0KA01-0AA2.jpg\" alt=\"\" class=\"wp-image-7947\" width=\"294\" height=\"294\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/12\/6ES7647-0KA01-0AA2.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/12\/6ES7647-0KA01-0AA2-150x150.jpg 150w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/12\/6ES7647-0KA01-0AA2-116x116.jpg 116w\" sizes=\"(max-width: 294px) 100vw, 294px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SIMATIC IoT2000 input\/output module<\/h2>\n\n\n\n<p><strong>IO shield for SIMATIC IOT2000 Industrial IoT Gateways<\/strong><br>The SIMATIC IOT2000 IO shield allows for direct connection of non-time-critical sensor data to the SIMATIC IOT2000 via digital and analog IOs.<\/p>\n\n\n\n<p><strong>Specifications<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table is-style-default\"><table class=\"\"><thead><tr><td colspan=\"2\" style=\"vertical-align:top\"><strong>Article number<\/strong><\/td><th style=\"vertical-align:top\"><strong>6ES7647-0KA01-0AA2<\/strong><br>SIMATIC IoT2000 input\/output module<\/th><\/tr><\/thead><tbody><tr><td colspan=\"3\"><strong>General information<\/strong><\/td><\/tr><tr><td colspan=\"2\">Product type designation<\/td><td>IOT2000<\/td><\/tr><tr><td colspan=\"3\"><strong>Installation type\/mounting<\/strong><\/td><\/tr><tr><td colspan=\"2\">Mounting<\/td><td>On Arduino interface<\/td><\/tr><tr><td colspan=\"2\">Design<\/td><td>Plug-in card<\/td><\/tr><tr><td colspan=\"3\"><strong>Supply voltage<\/strong><\/td><\/tr><tr><td colspan=\"2\">Type of supply voltage<\/td><td>24 V DC<\/td><\/tr><tr><td colspan=\"3\"><strong>Digital inputs<\/strong><\/td><\/tr><tr><td colspan=\"2\">Number of digital inputs<\/td><td>5<\/td><\/tr><tr><td colspan=\"3\"><em>Input voltage<\/em><\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Type of input voltage<\/td><td>DC<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;for signal &#8220;0&#8221;<\/td><td>&lt; 5 V DC<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;for signal &#8220;1&#8221;<\/td><td>&gt; 12 V DC<\/td><\/tr><tr><td colspan=\"3\"><em>Input current<\/em><\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;for signal &#8220;0&#8221;, max. (permissible quiescent current)<\/td><td style=\"vertical-align:top\">0.9&nbsp;mA<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;for signal &#8220;1&#8221;, typ.<\/td><td>2.1&nbsp;mA<\/td><\/tr><tr><td colspan=\"3\"><em>Input delay (for rated value of input voltage)<\/em> <em>for standard inputs<\/em><\/td><\/tr><tr><td colspan=\"2\">\u2014&nbsp;at &#8220;0&#8221; to &#8220;1&#8221;, max.<\/td><td>1.5&nbsp;ms<\/td><\/tr><tr><td colspan=\"2\">\u2014&nbsp;at &#8220;1&#8221; to &#8220;0&#8221;, max.<\/td><td>1.5&nbsp;ms<\/td><\/tr><tr><td colspan=\"3\"><strong>Digital outputs<\/strong><\/td><\/tr><tr><td colspan=\"2\">Type of digital output<\/td><td>transistor<\/td><\/tr><tr><td colspan=\"2\">Number of digital outputs<\/td><td>2<\/td><\/tr><tr><td colspan=\"2\">Short-circuit protection<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"3\"><em>Output voltage<\/em><\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Type of output voltage<\/td><td>DC<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;permissible voltage at output, min.<\/td><td>0&nbsp;V<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;permissible voltage at output, max.<\/td><td>28.8&nbsp;V<\/td><\/tr><tr><td colspan=\"3\"><em>Output current<\/em><\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;for signal &#8220;1&#8221; rated value<\/td><td>0.3&nbsp;A<\/td><\/tr><tr><td colspan=\"3\"><em>Parallel switching of two outputs<\/em><\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;for uprating<\/td><td>No<\/td><\/tr><tr><td colspan=\"3\"><em>Switching frequency<\/em><\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;with resistive load, max.<\/td><td>10&nbsp;Hz<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;with inductive load, max.<\/td><td>0.5&nbsp;Hz<\/td><\/tr><tr><td colspan=\"3\"><strong>Analog inputs<\/strong><\/td><\/tr><tr><td colspan=\"2\">Number of analog inputs<\/td><td>2<\/td><\/tr><tr><td colspan=\"2\"><em>Input ranges<\/em><\/td><td>&nbsp;<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Voltage<\/td><td>Yes; 0 to 10V<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Current<\/td><td>Yes; 0 to 20 mA<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Thermocouple<\/td><td>No<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Resistance thermometer<\/td><td>No<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Resistance<\/td><td>No<\/td><\/tr><tr><td colspan=\"3\"><em>Input ranges (rated values), voltages<\/em><\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;0 to +10 V<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"3\"><em>Input ranges (rated values), currents<\/em><\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;0 to 20 mA<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"3\"><strong>Analog value generation for the inputs<\/strong><\/td><\/tr><tr><td colspan=\"3\"><em>Integration and conversion time\/resolution per channel<\/em><\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Resolution with overrange (bit including sign), max.<\/td><td style=\"vertical-align:top\">9&nbsp;bit<\/td><\/tr><tr><td colspan=\"3\"><strong>Integrated Functions<\/strong><\/td><\/tr><tr><td colspan=\"3\"><em>Monitoring functions<\/em><\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Temperature monitoring<\/td><td>No<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Watchdog<\/td><td>No<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Status LEDs<\/td><td>No<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;Fan<\/td><td>No<\/td><\/tr><tr><td colspan=\"3\"><strong>EMC<\/strong><\/td><\/tr><tr><td colspan=\"3\"><em>Interference immunity against discharge of static electricity<\/em><\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Interference immunity against discharge of static electricity<\/td><td style=\"vertical-align:top\">\u00b14 kV contact discharge acc. to IEC 61000-4-2; \u00b18 kV air discharge acc. to IEC 61000-4-2<\/td><\/tr><tr><td colspan=\"3\"><em>Interference immunity against high-frequency electromagnetic fields<\/em><\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Interference immunity against high frequency radiation<\/td><td style=\"vertical-align:top\">10 V\/m for 80 &#8211; 1 000 MHz, 80% AM acc. to IEC 61000-4-3; 3 V\/m for 1.4 &#8211; 2 GHz, 80% AM acc. to IEC 61000-4-3; 1 V\/m for 2 &#8211; 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 150 kHz &#8211; 80 MHz, 80% AM acc. to IEC 61000-4-6<\/td><\/tr><tr><td colspan=\"3\"><em>Interference immunity to cable-borne interference<\/em><\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Interference immunity on supply cables<\/td><td style=\"vertical-align:top\">\u00b12 kV acc. to IEC 61000-4-4, burst; \u00b11 kV acc. to IEC 61000-4-5, surge symmetric; \u00b12 kV acc. to IEC 61000-4-5, surge asymmetric<\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Interference immunity on signal cables &gt;30m<\/td><td style=\"vertical-align:top\">\u00b12 kV acc. to IEC 61000-4-5, surge, length &gt; 30 m<\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Interference immunity on signal cables &lt; 30m<\/td><td style=\"vertical-align:top\">\u00b12 kV in accordance with IEC 61000-4-4, burst, length &gt; 30 m<\/td><\/tr><tr><td colspan=\"3\"><em>Interference immunity against voltage surge<\/em><\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;asymmetric interference<\/td><td>\u00b12 kV acc. to IEC 61000-4-5, surge asymmetric<\/td><\/tr><tr><td colspan=\"2\">\u25cf&nbsp;symmetric interference<\/td><td>\u00b11 kV acc. to IEC 61000-4-5, surge symmetric<\/td><\/tr><tr><td colspan=\"3\"><em>Interference immunity to magnetic fields<\/em><\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Interference immunity to magnetic fields at 50 Hz<\/td><td style=\"vertical-align:top\">100&nbsp;A\/m; to IEC 61000-4-8<\/td><\/tr><tr><td colspan=\"3\">Emission of conducted and non-conducted interference<\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Interference emission via line\/AC current cables<\/td><td style=\"vertical-align:top\">EN 61000-6-4:2007 +A1:2011<\/td><\/tr><tr><td colspan=\"3\"><strong>Degree and class of protection<\/strong><\/td><\/tr><tr><td colspan=\"2\">IP (at the front)<\/td><td>n.a.<\/td><\/tr><tr><td colspan=\"3\"><strong>Standards, approvals, certificates<\/strong><\/td><\/tr><tr><td colspan=\"2\">CE mark<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"2\">UL approval<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"2\">cULus<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"2\">KC approval<\/td><td>Yes; For use inside SIMATIC IoT2040<\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">EMC<\/td><td style=\"vertical-align:top\">CE, EN 61000-6-4:2007 +A1:2011, EN 61000-6-2:2005, EN 61000-6-3:2007 +A1:2011, EN 61000-6-1:2007<\/td><\/tr><tr><td colspan=\"3\"><strong>Ambient conditions<\/strong><\/td><\/tr><tr><td colspan=\"3\"><em>Ambient temperature during operation<\/em><\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Ambient temperature during operation<\/td><td style=\"vertical-align:top\">0 \u00b0C to 50 \u00b0C<\/td><\/tr><tr><td colspan=\"3\"><strong>Relative humidity<\/strong><\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Relative humidity<\/td><td style=\"vertical-align:top\">Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 \u00b0C (no condensation), storage \/ transport: 5 % to 95 % at 25 \/ 55 \u00b0C (no condensation)<\/td><\/tr><tr><td colspan=\"3\"><strong>Vibrations<\/strong><\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Vibration resistance during operation acc. to IEC 60068-2-6<\/td><td style=\"vertical-align:top\">Tested according to IEC 60068-2-6: 5 Hz to 9 Hz: 3.5 mm; 9 Hz to 200 Hz: 9.8 m\/s\u00b2<\/td><\/tr><tr><td colspan=\"3\"><strong>Shock testing<\/strong><\/td><\/tr><tr><td colspan=\"2\" style=\"vertical-align:top\">\u25cf&nbsp;Shock load during operation<\/td><td style=\"vertical-align:top\">Tested according to IEC 60068-2-27: 150 m\/s\u00b2, 11 ms<\/td><\/tr><tr><td colspan=\"3\"><strong>Operating systems<\/strong><\/td><\/tr><tr><td colspan=\"2\">without operating system<\/td><td>Yes<\/td><\/tr><tr><td colspan=\"2\"><strong>Dimensions<\/strong><\/td><td>&nbsp;<\/td><\/tr><tr><td colspan=\"2\">Width<\/td><td>75&nbsp;mm<\/td><\/tr><tr><td colspan=\"2\">Height<\/td><td>57&nbsp;mm<\/td><\/tr><tr><td colspan=\"2\">Depth<\/td><td>32&nbsp;mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>SIMATIC IoT2000 input\/output module IO shield for SIMATIC IOT2000 Industrial IoT GatewaysThe SIMATIC IOT2000 IO shield allows for direct connection of non-time-critical sensor data to the SIMATIC IOT2000 via digital and analog IOs. Specifications<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[28],"tags":[49,33],"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Khwanjai Nampromma","author_link":"https:\/\/ibcon.com\/main\/author\/khwanjai\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/ibcon.com\/main\/category\/brand\/siemens-product\/\" rel=\"category tag\">SIEMENS Product<\/a>","rttpg_excerpt":"SIMATIC IoT2000 input\/output module IO shield for SIMATIC IOT2000 Industrial IoT GatewaysThe SIMATIC IOT2000 IO shield allows for direct connection of non-time-critical sensor data to the SIMATIC IOT2000 via digital and analog IOs. Specifications","_links":{"self":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4854"}],"collection":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/comments?post=4854"}],"version-history":[{"count":4,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4854\/revisions"}],"predecessor-version":[{"id":7950,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4854\/revisions\/7950"}],"wp:attachment":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/media?parent=4854"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/categories?post=4854"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/tags?post=4854"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}