{"id":4898,"date":"2023-07-15T04:03:24","date_gmt":"2023-07-15T04:03:24","guid":{"rendered":"https:\/\/ibcon.com\/main\/?p=4898"},"modified":"2023-07-15T04:55:28","modified_gmt":"2023-07-15T04:55:28","slug":"miniature-circuit-breaker","status":"publish","type":"post","link":"https:\/\/ibcon.com\/main\/brand\/siemens-product\/miniature-circuit-breaker\/","title":{"rendered":"Miniature Circuit Breaker"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"640\" height=\"263\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/breaker.jpg\" alt=\"\" class=\"wp-image-4899\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/breaker.jpg 640w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/breaker-300x123.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/breaker-228x94.jpg 228w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Protecting electrical installations from damage<\/strong><\/h2>\n\n\n\n<p>The number of electrical loads is constantly increasing, which places an ever greater load on the electrical installation. In the event of an overload or short-circuit, miniature circuit breakers safely cut off the connected circuit and reliably protect electrical installations and equipment from damage. Miniature circuit breakers from the SENTRON portfolio are also simple to mount and install. The devices have a uniform design and, with the appropriate accessories, can be expanded by many additional functions. For industry, buildings or infrastructure \u2013 with our versatile portfolio, you will find a suitable miniature circuit breaker for any application.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Communication and measuring capable miniature circuit breakers<\/strong><\/h2>\n\n\n\n<p>In addition to the protective functions of the standard devices, the communication and measuring capable MCBs bring transparency to the final circuit and can react even before the fault occurs. The system availability is increased. Information on the switching status enables predictive maintenance.The standard 5SY MCBs, 5SP4 MCBs and 5SL MCBs can be easily expanded with the communication and measuring capable auxiliary witch \/ fault signal contact.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"640\" height=\"866\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/breaker_02.jpg\" alt=\"\" class=\"wp-image-4900\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/breaker_02.jpg 640w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/breaker_02-222x300.jpg 222w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/07\/breaker_02-86x116.jpg 86w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>Specifications<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\" style=\"font-size:14px\"><tbody><tr><td style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Article Number<\/strong><\/td><td style=\"vertical-align:top;background-color:#e3e3e3\"><strong>5SL6206-7<\/strong><\/td><td style=\"vertical-align:top;background-color:#e3e3e3\"><strong>5SL6216-7<\/strong><\/td><\/tr><tr><td colspan=\"3\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Model<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">product brand name<\/td><td style=\"vertical-align:top\">SENTRON<\/td><td style=\"vertical-align:top\">SENTRON<\/td><\/tr><tr><td>product description<\/td><td>Miniature circuit breaker 400 V 6kA, 2-pole, C, 6A<\/td><td>Miniature circuit breaker 400 V 6kA, 2-pole, C, 16A<\/td><\/tr><tr><td colspan=\"3\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>General technical data<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">number of poles<\/td><td style=\"vertical-align:top\">2<\/td><td style=\"vertical-align:top\">2<\/td><\/tr><tr><td style=\"vertical-align:top\">design of pole<\/td><td style=\"vertical-align:top\">2P<\/td><td style=\"vertical-align:top\">2P<\/td><\/tr><tr><td style=\"vertical-align:top\">tripping characteristic class<\/td><td style=\"vertical-align:top\">C<\/td><td style=\"vertical-align:top\">C<\/td><\/tr><tr><td style=\"vertical-align:top\">mechanical service life (operating cycles) typical<\/td><td style=\"vertical-align:top\">10 000<\/td><td style=\"vertical-align:top\">10 000<\/td><\/tr><tr><td style=\"vertical-align:top\">overvoltage category<\/td><td style=\"vertical-align:top\">III<\/td><td style=\"vertical-align:top\">III<\/td><\/tr><tr><td style=\"vertical-align:top\">degree of pollution<\/td><td style=\"vertical-align:top\">2<\/td><td style=\"vertical-align:top\">2<\/td><\/tr><tr><td colspan=\"3\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Voltage<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">type of voltage of the operating voltage<\/td><td style=\"vertical-align:top\">AC<\/td><td style=\"vertical-align:top\">AC<\/td><\/tr><tr><td style=\"vertical-align:top\">insulation voltage (Ui)<br>\u25cf with multi-phase operation at AC rated value<\/td><td style=\"vertical-align:top\"><br>440 V<\/td><td style=\"vertical-align:top\"><br>440 V<\/td><\/tr><tr><td colspan=\"3\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Supply voltage<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">supply voltage at AC rated value<\/td><td style=\"vertical-align:top\">400 V<\/td><td style=\"vertical-align:top\">400 V<\/td><\/tr><tr><td style=\"vertical-align:top\">value range of the supply voltage frequency<\/td><td style=\"vertical-align:top\">50\/60 Hz<\/td><td style=\"vertical-align:top\">50\/60 Hz<\/td><\/tr><tr><td style=\"vertical-align:top\">operating voltage<br>\u25cf with multi-phase operation at AC maximum<br>\u25cf at DC rated value maximum<\/td><td style=\"vertical-align:top\"><br>440 V<br>72 V<\/td><td style=\"vertical-align:top\"><br>440 V<br>72 V<\/td><\/tr><tr><td colspan=\"3\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Protection class<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">protection class IP<\/td><td style=\"vertical-align:top\">IP20, with connected conductors<\/td><td style=\"vertical-align:top\">IP20, with connected conductors<\/td><\/tr><tr><td colspan=\"3\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Switching capacity<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">switching capacity current<br>\u25cf according to EN 60898 rated value<br>\u25cf according to IEC 60947-2 rated value<\/td><td style=\"vertical-align:top\"><br>6 kA<br>6 kA<\/td><td style=\"vertical-align:top\"><br>6 kA<br>6 kA<\/td><\/tr><tr><td style=\"vertical-align:top\">energy limitation class<\/td><td style=\"vertical-align:top\">3<\/td><td style=\"vertical-align:top\">3<\/td><\/tr><tr><td colspan=\"3\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Dissipation<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">power loss [W] for rated value of the current at AC in hot<br>operating state per pole<\/td><td style=\"vertical-align:top\">0.7 W<\/td><td style=\"vertical-align:top\">1.8 W<\/td><\/tr><tr><td style=\"vertical-align:top\">suitability for operation<\/td><td style=\"vertical-align:top\">Residential buildings\/infrastructure<\/td><td style=\"vertical-align:top\">Residential buildings\/infrastructure<\/td><\/tr><tr><td colspan=\"3\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Product details<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">product feature<br>\u25cf halogen-free<br>\u25cf sealable<br>\u25cf silicon-free<\/td><td style=\"vertical-align:top\"><br>Yes<br>Yes<br>Yes<\/td><td style=\"vertical-align:top\"><br>Yes<br>Yes<br>Yes<\/td><\/tr><tr><td style=\"vertical-align:top\">product extension installable supplementary devices<\/td><td style=\"vertical-align:top\">Yes<\/td><td style=\"vertical-align:top\">Yes<\/td><\/tr><tr><td colspan=\"3\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Connections<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">connectable conductor cross-section solid<br>\u25cf minimum<br>\u25cf maximum<\/td><td style=\"vertical-align:top\"><br>0.75 mm\u00b2<br>25 mm\u00b2<\/td><td style=\"vertical-align:top\"><br>0.75 mm\u00b2<br>25 mm\u00b2<\/td><\/tr><tr><td style=\"vertical-align:top\">connectable conductor cross-section stranded<br>\u25cf minimum<br>\u25cf maximum<\/td><td style=\"vertical-align:top\"><br>0.75 mm\u00b2<br>25 mm\u00b2<\/td><td style=\"vertical-align:top\"><br>0.75 mm\u00b2<br>25 mm\u00b2<\/td><\/tr><tr><td style=\"vertical-align:top\">connectable conductor cross-section finely stranded with core end processing<br>\u25cf minimum<br>\u25cf maximum<\/td><td style=\"vertical-align:top\"><br><br>0.75 mm\u00b2<br>25 mm\u00b2<\/td><td style=\"vertical-align:top\"><br><br>0.75 mm\u00b2<br>25 mm\u00b2<\/td><\/tr><tr><td style=\"vertical-align:top\">tightening torque with screw-type terminals<br>\u25cf minimum<br>\u25cf maximum<\/td><td style=\"vertical-align:top\"><br>2.5 N\u00b7m<br>3 N\u00b7m<\/td><td style=\"vertical-align:top\"><br>2.5 N\u00b7m<br>3 N\u00b7m<\/td><\/tr><tr><td colspan=\"3\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Mechanical Design<\/strong><\/td><\/tr><tr><td>height<\/td><td>90 mm<\/td><td>90 mm<\/td><\/tr><tr><td>width<\/td><td>36 mm<\/td><td>36 mm<\/td><\/tr><tr><td>depth<\/td><td>76 mm<\/td><td>76 mm<\/td><\/tr><tr><td>installation depth<\/td><td>70 mm<\/td><td>70 mm<\/td><\/tr><tr><td>number of modular width units<\/td><td>2<\/td><td>2<\/td><\/tr><tr><td>mounting position<\/td><td>any<\/td><td>any<\/td><\/tr><tr><td>net weight<\/td><td>235 g<\/td><td>230 g<\/td><\/tr><tr><td colspan=\"3\" style=\"background-color:#e3e3e3\"><strong>Environmental conditions<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">ambient temperature during operation<br>\u25cf minimum<br>\u25cf maximum<\/td><td style=\"vertical-align:top\"><br>-25 \u00b0C<br>45 \u00b0C<\/td><td style=\"vertical-align:top\"><br>-25 \u00b0C<br>45 \u00b0C<\/td><\/tr><tr><td style=\"vertical-align:top\">ambient temperature during storage<br>\u25cf minimum<br>\u25cf maximum<\/td><td style=\"vertical-align:top\"><br>-40 \u00b0C<br>75 \u00b0C<\/td><td style=\"vertical-align:top\"><br>-40 \u00b0C<br>75 \u00b0C<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Protecting electrical installations from damage The number of electrical loads is constantly increasing, which places an ever greater load on the electrical installation. In the event of an overload or short-circuit, miniature circuit breakers safely cut off the connected circuit and reliably protect electrical installations and equipment from damage. Miniature [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[28],"tags":[54,33],"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Khwanjai Nampromma","author_link":"https:\/\/ibcon.com\/main\/author\/khwanjai\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/ibcon.com\/main\/category\/brand\/siemens-product\/\" rel=\"category tag\">SIEMENS Product<\/a>","rttpg_excerpt":"Protecting electrical installations from damage The number of electrical loads is constantly increasing, which places an ever greater load on the electrical installation. In the event of an overload or short-circuit, miniature circuit breakers safely cut off the connected circuit and reliably protect electrical installations and equipment from damage. Miniature [&hellip;]","_links":{"self":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4898"}],"collection":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/comments?post=4898"}],"version-history":[{"count":7,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4898\/revisions"}],"predecessor-version":[{"id":4913,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/4898\/revisions\/4913"}],"wp:attachment":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/media?parent=4898"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/categories?post=4898"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/tags?post=4898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}