{"id":5193,"date":"2023-08-04T08:09:23","date_gmt":"2023-08-04T08:09:23","guid":{"rendered":"https:\/\/ibcon.com\/main\/?p=5193"},"modified":"2023-08-04T08:44:47","modified_gmt":"2023-08-04T08:44:47","slug":"ethernet-ip-modules-adam-6100ei","status":"publish","type":"post","link":"https:\/\/ibcon.com\/main\/brand\/advantech-product\/ethernet-ip-modules-adam-6100ei\/","title":{"rendered":"EtherNet\/IP Modules: ADAM-6100EI"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6117EI.jpg\" alt=\"\" class=\"wp-image-5194\" width=\"331\" height=\"331\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6117EI.jpg 440w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6117EI-300x300.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6117EI-150x150.jpg 150w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6117EI-116x116.jpg 116w\" sizes=\"(max-width: 331px) 100vw, 331px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">EtherNet\/IP Modules: ADAM-6100EI<\/h2>\n\n\n\n<p>With daisy chain functionality and isolated design, industrial EtherNet\/IP remote I\/O modules provide facility management and remote data monitoring.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><br>Product List<\/h2>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td style=\"width:25%\">ADAM-6117EI<\/td><td>8AI EtherNet\/IP Fieldbus Remote I\/O<\/td><\/tr><tr><td style=\"width:25%\">ADAM-6150EI<\/td><td>8DI\/7DO EtherNet\/IP Fieldbus Remote I\/O<\/td><\/tr><tr><td style=\"width:25%\">ADAM-6151EI<\/td><td>16DI EtherNet\/IP Fieldbus Remote I\/O<\/td><\/tr><tr><td style=\"width:25%\">ADAM-6156EI<\/td><td>16DO EtherNet\/IP Fieldbus Remote I\/O<\/td><\/tr><tr><td style=\"width:25%\">ADAM-6160EI<\/td><td>6Relay EtherNet\/IP Fieldbus Remote I\/O<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-big-font-size\"><br><strong>Specifications<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\" style=\"font-size:12px\"><thead><tr><th style=\"vertical-align:top\">Part Number<\/th><th>ADAM-6117EI-AE<\/th><th>ADAM-6150EI-AE<\/th><th>ADAM-6151EI-AE<\/th><th>ADAM-6156EI-AE<\/th><th>ADAM-6160EI-AE<\/th><\/tr><\/thead><tbody><tr><td colspan=\"6\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Analog Input<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Channels<\/td><td>8<\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td style=\"vertical-align:top\">Input Range<\/td><td>\u00b10.15 V \u00b10.5 V, \u00b11 V, \u00b15 V, \u00b110 V, \u00b120 mA, 0~20 mA, 4~20 mA<\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td style=\"vertical-align:top\">lnput Type<\/td><td>V, mV, mA<\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td style=\"vertical-align:top\">Resolution(Bits)<\/td><td>16-bit<\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td style=\"vertical-align:top\">Sampling Rates(S\/s)<\/td><td>10 S\/s (sum)<\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td colspan=\"6\" style=\"background-color:#e3e3e3\"><strong>Isolated Digital Input<\/strong><\/td><\/tr><tr><td>Channels<\/td><td><\/td><td>8<\/td><td>16<\/td><td><\/td><td><\/td><\/tr><tr><td style=\"vertical-align:top\">Input Voltage<\/td><td><\/td><td>Dry Contact<br>Logic level 0: open<br>Logic level 1: close to GND<br>Wet Contact<br>Logic level 1: 10~30 VDC and -10~-30 VDC<br>Logic level 0: -3~3 VDC<\/td><td>Dry Contact<br>Logic level 0: open<br>Logic level 1: close to GND<br>Wet Contact<br>Logic level 1: 10~30 VDC and -10~-30 VDC<br>Logic level 0: -3~3 VDC<\/td><td><\/td><td><\/td><\/tr><tr><td colspan=\"6\" style=\"background-color:#e3e3e3\"><strong>Isolated Digital Output<\/strong><\/td><\/tr><tr><td>Channels<\/td><td><\/td><td>7<\/td><td><\/td><td>16<\/td><td><\/td><\/tr><tr><td>Output Type<\/td><td><\/td><td>Sink<\/td><td><\/td><td>Sink<\/td><td><\/td><\/tr><tr><td>Output Voltage<\/td><td><\/td><td>8~35 VDC<\/td><td><\/td><td>8~35 VDC<\/td><td><\/td><\/tr><tr><td>Sink Current<\/td><td><\/td><td>100 mA max.\/channel<\/td><td><\/td><td>100 mA max.\/channel<\/td><td><\/td><\/tr><tr><td colspan=\"6\" style=\"background-color:#e3e3e3\"><strong>Relay Output<\/strong><\/td><\/tr><tr><td>Channels<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>6<\/td><\/tr><tr><td>Contact Rating (Resistive)<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>5 A @ 30 VDC, 5 A @ 250 VAC<\/td><\/tr><tr><td>Relay Type<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>1 x Form A, 5 x Form C<\/td><\/tr><tr><td colspan=\"6\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Communications<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Interface<\/td><td>Ethernet<\/td><td>Ethernet<\/td><td>Ethernet<\/td><td>Ethernet<\/td><td>Ethernet<\/td><\/tr><tr><td colspan=\"6\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Environment<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Isolation Voltage<\/td><td>2,500 VDC<\/td><td>2,500 VDC<\/td><td>2,500 VDC<\/td><td>2,500 VDC<\/td><td>2,500 VDC<\/td><\/tr><tr><td style=\"vertical-align:top\">Operating Temperature<\/td><td>-10~70 \u00b0C (14~158 \u00b0F)<\/td><td>-10~70 \u00b0C (14~158 \u00b0F)<\/td><td>-10~70 \u00b0C (14~158 \u00b0F)<\/td><td>-10~70 \u00b0C (14~158 \u00b0F)<\/td><td>-10~70 \u00b0C (14~158 \u00b0F)<\/td><\/tr><tr><td colspan=\"6\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>General<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Connectors<\/td><td>2 x RJ45, 1 x 15-pin plug-in screw terminal, 1 x 5-pin plug-in screw terminal<\/td><td>2 x RJ45, 1 x 15-pin plug-in screw terminal, 1 x 5-pin plug-in screw terminal<\/td><td>2 x RJ45, 1 x 15-pin plug-in screw terminal, 1 x 5-pin plug-in screw terminal<\/td><td>2 x RJ45, 1 x 15-pin plug-in screw terminal, 1 x 5-pin plug-in screw terminal<\/td><td>2 x RJ45, 1 x 15-pin plug-in screw terminal, 1 x 5-pin plug-in screw terminal<\/td><\/tr><tr><td style=\"vertical-align:top\">Protocol<\/td><td>Ethernet\/IP<\/td><td>Ethernet\/IP<\/td><td>Ethernet\/IP<\/td><td>Ethernet\/IP<\/td><td>Ethernet\/IP<\/td><\/tr><tr><td colspan=\"6\" style=\"vertical-align:top;background-color:#e3e3e3\"><strong>Power Requirements<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Input Voltage<\/td><td>10~30 VDC<\/td><td>10~30 VDC<\/td><td>10~30 VDC<\/td><td>10~30 VDC<\/td><td>10~30 VDC<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>EtherNet\/IP Modules: ADAM-6100EI With daisy chain functionality and isolated design, industrial EtherNet\/IP remote I\/O modules provide facility management and remote data monitoring. Product List Specifications<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[26],"tags":[96,38,94,78],"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Khwanjai Nampromma","author_link":"https:\/\/ibcon.com\/main\/author\/khwanjai\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/ibcon.com\/main\/category\/brand\/advantech-product\/\" rel=\"category tag\">Advantech Product<\/a>","rttpg_excerpt":"EtherNet\/IP Modules: ADAM-6100EI With daisy chain functionality and isolated design, industrial EtherNet\/IP remote I\/O modules provide facility management and remote data monitoring. Product List Specifications","_links":{"self":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/5193"}],"collection":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/comments?post=5193"}],"version-history":[{"count":5,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/5193\/revisions"}],"predecessor-version":[{"id":5209,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/5193\/revisions\/5209"}],"wp:attachment":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/media?parent=5193"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/categories?post=5193"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/tags?post=5193"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}