{"id":5446,"date":"2023-08-25T04:10:16","date_gmt":"2023-08-25T04:10:16","guid":{"rendered":"https:\/\/ibcon.com\/main\/?p=5446"},"modified":"2023-08-25T04:59:47","modified_gmt":"2023-08-25T04:59:47","slug":"opc-ua-ethernet-i-o-modules-adam-6300","status":"publish","type":"post","link":"https:\/\/ibcon.com\/main\/brand\/advantech-product\/opc-ua-ethernet-i-o-modules-adam-6300\/","title":{"rendered":"OPC UA Ethernet I\/O Modules: ADAM-6300"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" loading=\"lazy\" width=\"1024\" height=\"576\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6300Series-1024x576.jpg\" alt=\"\" class=\"wp-image-5447\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6300Series-1024x576.jpg 1024w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6300Series-300x169.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6300Series-768x432.jpg 768w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6300Series-1536x864.jpg 1536w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6300Series-206x116.jpg 206w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/ADAM-6300Series.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><br>OPC UA Ethernet I\/O Modules: ADAM-6300<\/h2>\n\n\n\n<p>Industrial OPC UA Ethernet I\/O Modules with Modbus protocol converge OT\/IT with security, linking to SCADA and the cloud for remote monitoring<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/content-adam6300_01-1024x576.jpg\" target=\"_blank\" rel=\"noreferrer noopener\"><img decoding=\"async\" loading=\"lazy\" width=\"1024\" height=\"576\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/content-adam6300_01-1024x576.jpg\" alt=\"\" class=\"wp-image-5449\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/content-adam6300_01-1024x576.jpg 1024w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/content-adam6300_01-300x169.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/content-adam6300_01-768x432.jpg 768w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/content-adam6300_01-1536x864.jpg 1536w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/content-adam6300_01-206x116.jpg 206w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2023\/08\/content-adam6300_01.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><br>Product List<\/h2>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td style=\"width:25%\">ADAM-6350<\/td><td>18DI\/18DO IoT Modbus\/OPC UA Ethernet Remote I\/O<\/td><\/tr><tr><td style=\"width:25%\">ADAM-6360D<\/td><td>8Relay(SSR)\/14DI\/6DO IoT Modbus\/OPC UA Ethernet Remote I\/O<\/td><\/tr><tr><td style=\"width:25%\">ADAM-6317<\/td><td>8AI\/11DI\/10DO IoT Modbus\/OPC UA Ethernet Remote I\/O<\/td><\/tr><tr><td style=\"width:25%\">ADAM-6366<\/td><td>6 Relay\/18DI\/6DO IoT Modbus\/OPC UA Ethernet Remote I\/O<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-big-font-size\"><br><strong>Specifications<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\" style=\"font-size:14px\"><thead><tr><th style=\"vertical-align:top\">Part Number<\/th><th style=\"vertical-align:top\">ADAM-6350-A1<\/th><th style=\"vertical-align:top\">ADAM-6317-A1<\/th><\/tr><\/thead><tbody><tr><td colspan=\"3\" style=\"background-color:#e3e3e3;vertical-align:top\"><strong>Analog Input<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Channels<\/td><td style=\"vertical-align:top\">&#8211;<\/td><td style=\"vertical-align:top\">8 differential<\/td><\/tr><tr><td style=\"vertical-align:top\">Resolution(Bits)<\/td><td style=\"vertical-align:top\">&#8211;<\/td><td style=\"vertical-align:top\">16-bit with \u00b10.1% FSR accuracy @25\u00b0C for voltage input,<br>16-bit with \u00b10.2% FSR accuracy @25\u00b0C for current input<\/td><\/tr><tr><td style=\"vertical-align:top\">Input Range<\/td><td style=\"vertical-align:top\">&#8211;<\/td><td style=\"vertical-align:top\">\u00b1150 mV, \u00b1500 mV, \u00b11 V, \u00b15 V, \u00b110 V, \u00b120 mA, 0~20 mA, 4~20 mA, 0~150 mV, 0~500 mV, 0~1 V, 0~5 V, 0~10 V<\/td><\/tr><tr><td style=\"vertical-align:top\">Sampling Rates(S\/s)<\/td><td style=\"vertical-align:top\">&#8211;<\/td><td style=\"vertical-align:top\">10 or 100 (sum)<\/td><\/tr><tr><td colspan=\"3\" style=\"background-color:#e3e3e3;vertical-align:top\"><strong>Isolated Digital Input<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Channels<\/td><td style=\"vertical-align:top\">18<\/td><td style=\"vertical-align:top\">11<\/td><\/tr><tr><td style=\"vertical-align:top\">Input Voltage<\/td><td style=\"vertical-align:top\">Dry contact Logic level 0: close to GND, Logic level 1: open. Wet Contact Logic level 0: 0~3 VDC, Logic level 1: 10~30 VDC<\/td><td style=\"vertical-align:top\">Dry contact Logic level 0: close to GND, Logic level 1: open. Wet Contact Logic level 0: 0~3 VDC, Logic level 1: 10~30 VDC<\/td><\/tr><tr><td style=\"vertical-align:top\">Isolation Protection<\/td><td style=\"vertical-align:top\">2,500 VDC<\/td><td style=\"vertical-align:top\">2,500 VDC<\/td><\/tr><tr><td colspan=\"3\" style=\"background-color:#e3e3e3;vertical-align:top\"><strong>Isolated Digital Output<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Channels<\/td><td style=\"vertical-align:top\">18<\/td><td style=\"vertical-align:top\">10<\/td><\/tr><tr><td style=\"vertical-align:top\">Isolation Protection<\/td><td style=\"vertical-align:top\">2,500 VDC<\/td><td style=\"vertical-align:top\">2,500 VDC<\/td><\/tr><tr><td style=\"vertical-align:top\">Output Type<\/td><td style=\"vertical-align:top\">Sink<\/td><td style=\"vertical-align:top\">Sink<\/td><\/tr><tr><td style=\"vertical-align:top\">Sink Current<\/td><td style=\"vertical-align:top\">100 mA max.\/channel<\/td><td style=\"vertical-align:top\">100 mA max.\/channel<\/td><\/tr><tr><td colspan=\"3\" style=\"background-color:#e3e3e3;vertical-align:top\"><strong>Counter\/Encoder Input<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Max. Input Frequency<\/td><td style=\"vertical-align:top\">3 kHz<\/td><td style=\"vertical-align:top\">3 kHz<\/td><\/tr><tr><td style=\"vertical-align:top\">Channels<\/td><td style=\"vertical-align:top\">6<\/td><td style=\"vertical-align:top\">6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-big-font-size\"><br><strong>Specifications<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\" style=\"font-size:14px\"><thead><tr><th style=\"vertical-align:top\">Part Number<\/th><th style=\"vertical-align:top\">ADAM-6360D-A1<\/th><th style=\"vertical-align:top\">ADAM-6366-A1<\/th><\/tr><\/thead><tbody><tr><td colspan=\"3\" style=\"background-color:#e3e3e3;vertical-align:top\"><strong>Relay Output<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Channels<\/td><td style=\"vertical-align:top\">8 PhotoMOS SPST Form A<\/td><td style=\"vertical-align:top\">6 Form A<\/td><\/tr><tr><td style=\"vertical-align:top\">Contact Rating (Resistive and Inductive Load)<\/td><td style=\"vertical-align:top\">1 A @ 25 \u00b0C @ 30 VDC, 0.7 A @ 70 \u00b0C @ 30 VDC<\/td><td style=\"vertical-align:top\">2 A @ 30 VDC, 0.25 A @ 250 VAC<\/td><\/tr><tr><td colspan=\"3\" style=\"background-color:#e3e3e3;vertical-align:top\"><strong>Isolated Digital Input<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Channels<\/td><td style=\"vertical-align:top\">14<\/td><td style=\"vertical-align:top\">18<\/td><\/tr><tr><td style=\"vertical-align:top\">Input Voltage<\/td><td style=\"vertical-align:top\">Dry contact Logic level 0: close to GND, Logic level 1: open. Wet Contact Logic level 0: 0~3 VDC, Logic level 1: 10~30 VDC<\/td><td style=\"vertical-align:top\">Dry contact Logic level 0: close to GND, Logic level 1: open. Wet Contact Logic level 0: 0~3 VDC, Logic level 1: 10~30 VDC<\/td><\/tr><tr><td style=\"vertical-align:top\">Isolation Protection<\/td><td style=\"vertical-align:top\">2,500 VDC<\/td><td style=\"vertical-align:top\">2,500 VDC<\/td><\/tr><tr><td colspan=\"3\" style=\"background-color:#e3e3e3;vertical-align:top\"><strong>Isolated Digital Output<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Channels<\/td><td style=\"vertical-align:top\">6<\/td><td style=\"vertical-align:top\">6<\/td><\/tr><tr><td style=\"vertical-align:top\">Isolation Protection<\/td><td style=\"vertical-align:top\">2,500 VDC<\/td><td style=\"vertical-align:top\">2,500 VDC<\/td><\/tr><tr><td style=\"vertical-align:top\">Output Type<\/td><td style=\"vertical-align:top\">Sink<\/td><td style=\"vertical-align:top\">Sink<\/td><\/tr><tr><td style=\"vertical-align:top\">Sink Current<\/td><td style=\"vertical-align:top\">100 mA max.\/channel<\/td><td style=\"vertical-align:top\">100 mA max.\/channel<\/td><\/tr><tr><td colspan=\"3\" style=\"background-color:#e3e3e3;vertical-align:top\"><strong>Counter\/Encoder Input<\/strong><\/td><\/tr><tr><td style=\"vertical-align:top\">Max. Input Frequency<\/td><td style=\"vertical-align:top\">3 kHz<\/td><td style=\"vertical-align:top\">3 kHz<\/td><\/tr><tr><td style=\"vertical-align:top\">Channels<\/td><td style=\"vertical-align:top\">6<\/td><td style=\"vertical-align:top\">6<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>OPC UA Ethernet I\/O Modules: ADAM-6300 Industrial OPC UA Ethernet I\/O Modules with Modbus protocol converge OT\/IT with security, linking to SCADA and the cloud for remote monitoring Product List Specifications Specifications<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[26],"tags":[104,38,105,78],"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Khwanjai Nampromma","author_link":"https:\/\/ibcon.com\/main\/author\/khwanjai\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/ibcon.com\/main\/category\/brand\/advantech-product\/\" rel=\"category tag\">Advantech Product<\/a>","rttpg_excerpt":"OPC UA Ethernet I\/O Modules: ADAM-6300 Industrial OPC UA Ethernet I\/O Modules with Modbus protocol converge OT\/IT with security, linking to SCADA and the cloud for remote monitoring Product List Specifications Specifications","_links":{"self":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/5446"}],"collection":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/comments?post=5446"}],"version-history":[{"count":15,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/5446\/revisions"}],"predecessor-version":[{"id":5472,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/5446\/revisions\/5472"}],"wp:attachment":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/media?parent=5446"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/categories?post=5446"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/tags?post=5446"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}