{"id":7438,"date":"2024-06-17T10:38:28","date_gmt":"2024-06-17T10:38:28","guid":{"rendered":"https:\/\/ibcon.com\/main\/?p=7438"},"modified":"2024-06-17T10:38:29","modified_gmt":"2024-06-17T10:38:29","slug":"cl-212-e","status":"publish","type":"post","link":"https:\/\/ibcon.com\/main\/brand\/cl-212-e\/","title":{"rendered":"CL-212-E"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/CL-212-E_la01.png\" alt=\"\" class=\"wp-image-7440\" width=\"329\" height=\"329\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/CL-212-E_la01.png 661w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/CL-212-E_la01-300x300.png 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/CL-212-E_la01-150x150.png 150w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/CL-212-E_la01-116x116.png 116w\" sizes=\"(max-width: 329px) 100vw, 329px\" \/><\/figure>\n\n\n\n<p>PM2.5\/CO2\/Temperature\/Humidity\/ Dew Point Data Logger Module<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Features<\/strong><\/h2>\n\n\n\n<ul>\n<li>Able to record PM2.5, CO2, Temperature, Humidity and Dew Point Measurements<\/li>\n\n\n\n<li>Non-dispersive Infrared (NDIR) CO2 Sensor<\/li>\n\n\n\n<li>Up to 450,000 records with date and time stamps<\/li>\n\n\n\n<li>Supports the DCON, Modbus RTU\/TCP, and MQTT Protocols<\/li>\n\n\n\n<li>Includes RS-485\/Ethernet Communication Interfaces<\/li>\n\n\n\n<li>Relay Output for Alarm or IAQ Device Control<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><br><strong>Introduction<\/strong><\/h2>\n\n\n\n<p>The CL-200 series of data logger devices can be used to record PM2.5, CO, CO2, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records.<\/p>\n\n\n\n<p>Real-time data can be accessed from the CL-200 data logger from anywhere and at any time using the free Windows software, the iOS App, or the Android App, as long as they are connected to the same local network as the data logger.<\/p>\n\n\n\n<p>Support is provided for common industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machine-to-machine (M2M)\/)IoT (Internet of Things) connectivity protocol \u2013 MQTT. The CL-200 data logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, ensuring trouble-free maintenance in distributed control systems.<\/p>\n\n\n\n<p><br><strong>Supports the MQTT Protocol for IoT Applications<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"450\" height=\"226\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/cl-211-e_in01.jpg\" alt=\"\" class=\"wp-image-7439\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/cl-211-e_in01.jpg 450w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/cl-211-e_in01-300x151.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/cl-211-e_in01-228x116.jpg 228w\" sizes=\"(max-width: 450px) 100vw, 450px\" \/><\/figure>\n\n\n\n<p><br><strong>Multi-platform Remote Access Software<\/strong><\/p>\n\n\n\n<p>Real-time data from the CL-200 data logger can be accessed from anywhere and at any time using the iAir Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the data logger.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"450\" height=\"211\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/cl-211-e_in02.jpg\" alt=\"\" class=\"wp-image-7441\" srcset=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/cl-211-e_in02.jpg 450w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/cl-211-e_in02-300x141.jpg 300w, https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/cl-211-e_in02-228x107.jpg 228w\" sizes=\"(max-width: 450px) 100vw, 450px\" \/><\/figure>\n\n\n\n<p><br><strong>Simple and Powerful Utility<\/strong><\/p>\n\n\n\n<p>The iAir Utility is a powerful tool that is designed for confi guring the modules, monitoring real-time data, grouping DL-300 and CL-200 modules to view and manage the status of distribution groups, downloading log data, which can be exported to a CSV file that can then be imported into any industry-standard software or spreadsheet for analysis.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"535\" height=\"342\" src=\"https:\/\/ibcon.com\/main\/wp-content\/uploads\/2024\/06\/dl-300_utility_software.gif\" alt=\"\" class=\"wp-image-7442\"\/><\/figure>\n\n\n\n<p><br><strong>Ordering Information<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\" style=\"max-width:100%\"><thead><tr><th style=\"width:25%\">PRODUCT SERIES<\/th><th>DESCRIPTION<\/th><\/tr><\/thead><tbody><tr><td style=\"width:25%\">CL-212-E\u00a0\u00a0\u00a0\u00a0\u00a0CR<\/td><td>PM2.5\/CO2\/Temperature\/Humidity\/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Specifications<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Temperature Measurement<\/strong><\/td><td><\/td><\/tr><tr><td>Range<\/td><td>-10 ~ +50\u00b0C<\/td><\/tr><tr><td>Resolution<\/td><td>0.1\u00b0C<\/td><\/tr><tr><td>Accuracy<\/td><td>\u00b10.6\u00b0C<\/td><\/tr><tr><td><strong>Humidity Measurement<\/strong><\/td><td><\/td><\/tr><tr><td>Range<\/td><td>0 ~ 100% RH, Non-condensing<\/td><\/tr><tr><td>Resolution<\/td><td>0.1% RH, Non-condensing<\/td><\/tr><tr><td>Accuracy<\/td><td>\u00b15% RH, Non-condensing<\/td><\/tr><tr><td><strong>Dew Point<\/strong><\/td><td><\/td><\/tr><tr><td>Range<\/td><td>Calculated using temperature and relative humidity<\/td><\/tr><tr><td>Resolution<\/td><td>0.1\u00b0C<\/td><\/tr><tr><td><strong>CO2 Measurement<\/strong><\/td><td><\/td><\/tr><tr><td>Range<\/td><td>0 to 9999 ppm (NDIR)<\/td><\/tr><tr><td>Resolution<\/td><td>1 ppm<\/td><\/tr><tr><td>Accuracy<\/td><td>\u00b140 ppm \u00b13% of measured value<\/td><\/tr><tr><td>Response Time<\/td><td>120 seconds<\/td><\/tr><tr><td>Warm-up Time<\/td><td>5 minutes<\/td><\/tr><tr><td><strong>PM2.5 Measurement<\/strong><\/td><td><\/td><\/tr><tr><td>Range<\/td><td>0 ~ 400 \u03bcg\/m3<\/td><\/tr><tr><td>Resolution<\/td><td>1\u03bcg\/m3<\/td><\/tr><tr><td>Response Time<\/td><td>&lt;= 1 min.<\/td><\/tr><tr><td><strong>System<\/strong><\/td><td><\/td><\/tr><tr><td>Alarm<\/td><td>PM2.5\/RH\/Temperature<\/td><\/tr><tr><td>Real Time Clock<\/td><td>Yes<\/td><\/tr><tr><td>Data Logger<\/td><td>Yes, up to 450,000 records<\/td><\/tr><tr><td><strong>Relay Output<\/strong><\/td><td><\/td><\/tr><tr><td style=\"vertical-align:top\">Channels<\/td><td>1 x Form A, SPST<br>30 VDC @ 16 A or 250 VAC @ 16 A<\/td><\/tr><tr><td><strong>Ethernet<\/strong><\/td><td><\/td><\/tr><tr><td style=\"vertical-align:top\">Ports<\/td><td>10\/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI\/MDIX, LED indicators)<\/td><\/tr><tr><td><strong>COM Ports<\/strong><\/td><td><\/td><\/tr><tr><td style=\"vertical-align:top\">Ports<\/td><td>1 x RS-485<br>1 x Ethernet<\/td><\/tr><tr><td style=\"vertical-align:top\">Protocol<\/td><td>DCON and Modbus\/RTU (RS-485)<br>Modbus TCP and MQTT (Ethernet)<\/td><\/tr><tr><td><strong>Power<\/strong><\/td><td><\/td><\/tr><tr><td style=\"vertical-align:top\">Consumption<\/td><td>Non-PoE: 2.9 W (Max.)<br>PoE: 3.22 W (Max.)<\/td><\/tr><tr><td>Powered from Terminal Block<\/td><td>+12 ~ +48 VDC<\/td><\/tr><tr><td><strong>Mechanical<\/strong><\/td><td><\/td><\/tr><tr><td>Dimensions (mm)<\/td><td>\u00d8 150 x 53 (\u00d8 x H)<\/td><\/tr><tr><td>Installation<\/td><td>Ceiling Mounting\/Wall Mounting<\/td><\/tr><tr><td>Ingress Protection Rating<\/td><td>IP20<\/td><\/tr><tr><td><strong>Environment<\/strong><\/td><td><\/td><\/tr><tr><td>Operating Temperature<\/td><td>0 ~ 50\u00b0C<\/td><\/tr><tr><td>Storage Temperature<\/td><td>-30 ~ +75\u00b0C<\/td><\/tr><tr><td>Humidity<\/td><td>10 ~ 90% RH, Non-condensing<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>PM2.5\/CO2\/Temperature\/Humidity\/ Dew Point Data Logger Module Features Introduction The CL-200 series of data logger devices can be used to record PM2.5, CO, CO2, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records. Real-time data can be accessed [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[157],"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"Khwanjai Nampromma","author_link":"https:\/\/ibcon.com\/main\/author\/khwanjai\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/ibcon.com\/main\/category\/brand\/\" rel=\"category tag\">Product Brand<\/a>","rttpg_excerpt":"PM2.5\/CO2\/Temperature\/Humidity\/ Dew Point Data Logger Module Features Introduction The CL-200 series of data logger devices can be used to record PM2.5, CO, CO2, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records. Real-time data can be accessed [&hellip;]","_links":{"self":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/7438"}],"collection":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/comments?post=7438"}],"version-history":[{"count":1,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/7438\/revisions"}],"predecessor-version":[{"id":7443,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/posts\/7438\/revisions\/7443"}],"wp:attachment":[{"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/media?parent=7438"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/categories?post=7438"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ibcon.com\/main\/wp-json\/wp\/v2\/tags?post=7438"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}